• Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier
  • Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier
  • Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier
  • Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

Logo Printing: Without Logo Printing
Installation Type: Panel Mounting
Display Digits: 4 digits
Customization:
Shipping Cost:

Estimated freight per unit.

about shipping cost and estimated delivery time.
Payment Method: visa mastercard discover JCB diners club american express T/T
  Initial Payment Full Payment
Currency: US$
Return&refunds: You can apply for a refund up to 30 days after receipt of the products.
From payment to delivery, we protect your trading.
Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier pictures & photos
Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier
US $16-22.5 / pieces
Min. Order: 1 pieces
Manufacturer/Factory & Trading Company
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Fujian, China
High Repeat Buyers Choice
More than 50% of buyers repeatedly choose the supplier
Years of Export Experience
The export experience of the supplier is more than 10 years
In-stock Capacity
The supplier has In-stock capacity
Fast Delivery
The supplier can deliver the goods within 15 days
to see all verified strength labels (25)
  • Overview
  • Product List
  • Product Overviews
  • Load cell Accessorie
  • Company Information
  • Packaging & Shipping
Overview

Basic Info.

Model NO.
PY-V-SP
Display Type
LED
Accuracy Grade
0.1G
IP Rating
IP65
Certification
CE/RoHS
Customized
Customized
Usage
Signal Amplifier / Vonvert
Description
Load Cell Amplifier
Input Signal
Mv/V
Size
145/115X80X46mm
Output Signal
0-5V, 0-10V, 4-20mA (Optional)
Working Temperature
-20~80 ºC
Item
Load Cell Amplifier
Working Temp.
-10--70 Degree
Type
Load Cell Amplifier
Load Cell Connection
1- 4 Sensors
Output
4-20mA 0-5V 0-10V
Voltage
12-24 VDC
Display
Metal Case Support
Specification
Custom size
Trademark
Sensorcon
Origin
Guangdong, China
HS Code
8533211000
Production Capacity
1000 Piece/Pieces Per Month

Packaging & Delivery

Package Size
20.00cm * 10.00cm * 10.00cm
Package Gross Weight
0.500kg

Product Description

Weight transmitter 0-5v 0-10v 4-20mA output load cell amplifier

 

Product List

 

 

Sensorcon Product Lists
Strain Gauge Load Cell Torque Sensor Display
Linear Strain gauge-AA Wireless sensor Slip ring rotary torque sensor Platform scale display
Half bridge strain gauge-BB,HA,GB,FB Micro load cell Contactless rotary torque sensor Truck scale display
Shear/torque strain gauge-AB,HA Single point load cell Static torque sensor Controller
Full bridge strain gauge-EB, FG,FD Button load cell Meters Junction box 
Tee Rosettes strain gauge-CA,BA Shear beam load cell Coupling Big screen display
Round type strain gauge S type load cell   Amplifier
Semi-conductor strain gauge Column load cell    
  Bridge type load cell    
Product Overviews

 

 

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Size:

 

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Features:

 Plastic housing, durable, cost-effective

Housing and wire joints are waterproof design, good sealing

High precision amplifier circuit, good stability

Anti-jamming performance

Wide sensitivity input range

power supply with reverse protection, surge protection, overcurrent protection

Sensor excitation voltage adjustable

Portable, small size, light weight, easy to install

Suitable for weighing, pull push force, torque, tension and other strain sensor

 

 

Parameter

 

 

Mode

 PY-V-SP

Input Signal

 mV

 Sensitivity range

Standard: 1MV/V, 1.5MV/V, 2MV/V, 3MV/V
Optional: 0.5MV/V, 4MV/V, 5MV/V ,6MV/V

 Load cell Excitation Voltage

 5~15VDC(Adjustable)

 Operating Temperature

 -20~60

 Operating Humidity

 <90%RH

 Protection grade

 IP65

 Installation

 Housing fixing

 Housing material

 ABS

 Working Excitation voltage

 Standard: 12VDC, Optional: 24VDC

 Output signal

 Current:4~20mA, 0~10mA, 0~20mA

 Voltage:0~5V, 0~10V, 1~5V, ±5V, ±10V

 Please notify us which output you want when place order
Customized output for voltage output is supported

 Accuracy

 Current output type ≥ 0.05%F.S

 Voltage output type ≥ 0.1%F.S

 Load cell connection

 At most 4 units of load cell in 350 ohm

 

 

Connection:

 

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Wire definition

 INPUT

 E+

 S+

 S-

 GND

 GNDD

 Load cell Input

 Load cell Exc +

 Load cell Signal+

 Load cell Signal-

Load cell Exc -

Shield

 OUTPUT

 24V

 Out

 GND

 GNDD

 

Transmitter output

Transmitter Exc+

Transmitter Signal output

 Transmitter Exc-(0V)

 Shield

 

 VR

 Zero

 Span

 Sensor bridge voltage adjustment potentiometer

 ZERO C potentiometer

 Full-scale control point potentiometer

I Zero-Current type, V Zero-Voltage type

I Span-Current type, V Span-Voltage type

 

 

 

Calibration:

 

1. Excitation voltage regulation

1.1 Transmitter 24V power supply,

a) When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V,

Excitation voltage is adjusted to 8-10.5V, (load ≤ 500Ω), factory default setting is 10.1V,

b) When output signal is 0-10V, excitation voltage is adjusted to 11-12VDC, (load ≤ 500Ω), factory default setting is 11V;

 

1.2 Transmitter 12V power supply

When output signal is 0-10mA, 0-20mA, 4-20mA, 0-5V, 1-5V and ± 5V, the excitation voltage is adjusted to 6-8.5V, (load ≤ 320Ω), factory default setting is 8.01V

 

1.3 User can adjust the "VR" according to actual situation. Adjust excitation voltage according to the sensor impedance but should not be higher than the max. Excitation voltage of load cell otherwise it will cause damage to the sensor or the sensor will not work properly.

 

2. Zero adjustment

First leave the system under no-load state, adjust the "ZERO" potentiometer to adjust the zero deviation.

Till the indication is to zero.

 

3. Gain adjustment

Add certain weight to the system, (recommend 60% to 100% full scale), Calculate output value based on the ratio of added weight and the max. measuring value. Adjust the "SPAN" potentiometer till the indicator is to Load ratio indication

 

4. Re-examination

leave the system under no-load state, measure zero output; add certain weight, measure the output again and see whether it is in line with the expected gain. If not, please repeat steps 2, 3

 

Note: After the adjustment is done, fix the end of the potentiometer with a sealant or glue to prevent any changing of potentiometer's resistance from vibration

 

 

Terms and Conditions

1, in strict accordance with the definition of wiring, with particular attention to distinguish between the sensor and the output side, the wrong wiring may cause no output or damage.

2, Except the potentiometer, all other electronic components should not have any change.

 

3, the device should be installed to the place without vibration impact, the installation should be reliable, beware of bumps and no strong corrosive gas around

 

Load cell Accessorie

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Company Information

Sensor and Control Co., Ltd. was founded in 2006, mainly engaged in Torque Sensor, Load Cell, Pressure Transducer, Strain Gauges and Weighing Indicators. Since establishment, we insist the guidelines of "Customer Oriented, Quality Focused, Professional Service "All products we supply are environment friendly and has passed RoHS test.

 

Sensorcon, in accordance with the principle of the introduction of advanced professional ultrasonic gas cleaning, clean Room patches, automatic temperature compensation and detection, high and low temperature testing and thermal experiments, laser welding and printing, CAD design, manufacturing and testing sensor test equipment and production technology ,manufacture all varieties of sensors, high precision, stable performance and also has antiseptic, waterproof, anti-explosion, anti-lightning, etc favored deeply by users.

 

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

 

 

Packaging & Shipping

Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

From payment to delivery, we protect your trading.
Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier pictures & photos
Weight Transmitter 0-5V 0-10V 4-20mA Output Load Cell Amplifier
US $16-22.5 / pieces
Min. Order: 1 pieces
Gold Member Since 2024

Suppliers with verified business licenses

Secured Trading Service
Manufacturer/Factory & Trading Company
Number of Employees
9
Year of Establishment
2014-06-03