Customization: | Available |
---|---|
Pattern: | Column Cylinder Type |
Transform Type: | Resistance Strain |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
SC490B tall through hole bolt load cell in sensors
Features:
1, SNC compression column load cells are ideally suited to high accuracy applications in truck and railway scales, tank and silo weighing and in heavy duty industrial scales.
2, Low profile pancake load cell for use in process weighing applications. Combined with the SC4810M, 4828M weigh module, this is the great choice for applications in food and pharmaceutical production sectors.
3, SNC compression load cells defy harsh environments with stainless steel construction and hermetic sealing technology. Various models are available with different cable lengths; with/without connectors.
SC490B tall through hole bolt load cell in sensors
Diameters: mm
Parameters:
SC490B tall through hole bolt load cell in sensors | |
Application | Oil field applying |
Model | SC490B |
Capacity | 100KN, 150KN, 200KN |
rated output | 1.0±0.05mV/V 4-20mA (optional) |
Accuracy class | C2 |
maximum number of verification intervals | 1500Nmax |
Minimum loadcell cerification intervals | Emax/2000 Vmin |
Combined error | ≤±0.030 % RO |
Creep | 0.05 %RO/30min |
Temp. effect on sensitivity | 0.2 %RO/ |
Temp.effect on zero | 0.1 %RO/ |
Zero balance | ±1.0 %RO |
Input resistance | 700±5 ohm |
Output resistance | 700±5 ohm |
insulation resistance | 5000 MΩ(50V) |
Recommended excitation voltage | 10-15V |
Compensated temperature range | -10-+40 |
operating temperature range | -35-+80 |
safe overload | 150 %RO |
Ultimate overload | 200%RO |
loadcell material | Alloy steel 2Cr13 stainless steel |
Connecting cable | Avation special use connector |
Method of connecting wire | Red- input+, black- Input-. Green- Output+, White- output - |
Note:
Below are column load cell series, you can find other similar cylindrical load cell in our web, if you cannot find it or you have special requirement, please send us e-mail snc at sensor-con doc com with model name or the special requirement you may have. We will come up with a solution for all of your Canister load cell requirement.
Load cells should be selected after considering the following points.
1.1. Loading Conditions
Determine the loading conditions of the load cell (tension, compression, bending, etc.) that best suit the
kind of weighing you would like to perform.
1.2. Rated Capacity
The following points should be considered when selecting a rated capacity.
2.1. Display of the Required Resolution
When the minimum weighing value (1 digit) is small compared to the rated capacity, the load cell
output per digit should be above the input sensitivity of the indicator.
Force applied onto the weighing pan is converted into electrical signals by the load cell and output to
the indicator.
2.2. The Strength of the Load Cells
1) Platform scales
When making a platform scale using a single-point load cell (LC4001 - LC4212), it is acceptable for the
weighing capacity of the scale to be equal to the rated capacity of the load cell. For instance, if we want
to make a scale with a capacity of 100 kg, we can use a load cell whose rated capacity is 100 kg.
However, the initial (tare) load must not exceed the safe tare limit (maximum dead weight) of the load
cell. If the initial load is very large, the rated capacity + the safe tare limit is treated as the rated
capacity.
2) Industrial hopper scales, etc.
The rated capacity of a load cell for purposes other than platform scales can be determined as follows.
However, the rated capacity must be sufficiently large if overloading or transverse loading may occur
2.3. Accuracy of Measurement
Load cell specifications must be checked to ensure that they satisfy the required accuracy of
measurement. The factors that influence the accuracy are nonlinearity, hysteresis error, repeatability,
and temperature effects on zero balance and span. Recently, it is more common to express nonlinearity,
hysteresis error, and repeatability together as the combined error.
Our service
We are a professional high-tech enterprise engaging in the development, sales and customized service of
Strain gauge / strain gauges
pressure sensor / pressure transmitters
Load cell weigh sensor
Weigh indicators / junction box
Big screen display
Truck scale / portable axle scales
They are widely used in aerospace, automobile, chemical, mine, electric power, food,
medicine, metallurgy, paper-making, petroleum, railroad and water conservation industry etc.
1, All of your weighing components' enquires will be answered within 24 hours.
2, We can provide you not only weighing products but whole weigh system idea and professional service in weighing industries, like load cell, strain gauges, indicators, big screen display and axle scales.
3, Customized design of weighing components/ device is available, OEM and ODM are welcome.
4, Exclusive and unique weigh products can be provided by our professional and well-trained engineers and staff.
5, Special discount and protection of sales area are provided to our weight weighing distributors.